Back to List

ITI Hydraulik - In Ground Pop-In

Head Drawing

diagram

Other Versions

No other drawings

Installation Locations in N. America

Installation Location

Cylinder Notes

  • Manufactured after 2005
  • Easily confused with ITI Hydraulik Two Seal
  • Pop-In VS. Two Seal Heads: Pop-in has 2 ports and is shorter. Two Seal has 3 ports and is taller.

Packing Sets

Plunger Diameter Packing Set number
3-1/2 9EA169-09
4 9EA169-13
4-3/8 9EA169-14
4-7/16 9EA169-15
4-1/2 9EA169-16
4-5/8 9EA169-17
4-15/16 9EA169-31
5 9EA169-18
5-7/16 9EA169-19
5-1/2 9EA169-20
6 9EA169-21
6-1/2 9EA169-22
6-9/16 9EA169-23
7-1/2 9EA169-24
8 9EA169-25
8-9/16 9EA169-26
9 9EA169-32
9-1/2 9EA169-27
9-9/16 9EA169-28
10-5/8 9EA169-33
10-11/16 6EA169-29
12-11/16 6EA169-30

Packing Notes

  • All sizes shown above are 1/2 Cross Section
  • Other sizes available, call with plunger size and cross section.
  • Wear Ring available. Please inquire

Packing Set Contents

Wiper
Seal
O Ring

Packing Alternatives

Call if you have one of these extreme conditions
Condition Recommendation
Damaged Plunger Damaged Plunger 600 Series